Microlife Microlife
  • Prodotti Domiciliari
    • BP A6 Advanced Easy_red_logo Pressione arteriosa
    • trasp_NON CONTACT Febbre
    • trasp_NEB NANO_half-acc_PRINT_LOcopy1 Terapia respiratoria
    • trasp_WS 80n_half Controllo del peso
    • Software_downloads_allg Software
  • Prodotti Professionali
    • WatchBP Office ABI_front_cuff WatchBP Office
    • WatchBP O3 Ambulatory AFIB_front_cuff WatchBP 03
    • WatchBP Home A_front_cuff WatchBP Home
    • Cuff-Ankle Bracciali e Accessori
    • Software Software
  • Tecnologie
  • Magazine
  • Azienda
    • aboutus Chi siamo
    • Events Eventi e News
    • contact Contatti
    • History Storia
ITALIA
Italiano
Europe
  • EUROPE - English
  • CZECHIA - Čeština
  • DANMARK - Dansk
  • DEUTSCHLAND - Deutsch
  • ESPAÑA - Español
  • FRANCE - Français
  • HRVATSKA - Hrvatski
  • ITALIA - Italiano
  • LATVIJA - Latviešu
  • LIETUVA - Lietuvių
  • MAGYARORSZÁG - Magyar
  • NEDERLAND - Nederlands
  • ÖSTERREICH - Deutsch
  • POLSKA - Polski
  • PORTUGAL - Português
  • SCHWEIZ - Deutsch
  • SLOVENSKO - Slovenčina
  • SLOVENIJA - Slovenščina
  • SUOMI - Suomi
  • SCHWEIZ - Français
  • UK - English
  • ΕΛΛΆΔΑ - Ελληνικά
  • БЪЛГАРИЯ - Български
  • СРБИЈА - Српски
  • УКРАЇНА - Українська
  • TÜRKIYE - Türkçe
  • РОССИЯ - Русский
  • БЕЛАРУСЬ - Русский
Asia
  • ASIA PACIFIC - English
  • VIỆT NAM - Tiếng Việt
  • ประเทศไทย - ไทย
  • 中国 - 中文
  • 台灣 - 中文
Middle East and North Africa
  • MENA - Arabic عربى
USA, Latin America
  • US - English
  • AMÉRICA DEL SUR - Español
  • COLOMBIA - Español
  • MÉXICO - Español
Menu
microlife-bloodpressure-measurement-man Flow

Validation of the Microlife BP 3BTO-A oscillometric blood pressure monitoring device according to a modified British Hypertension Society protocol

Home > Prodotti Professionali
Share

Alexandra C. Cuckson, Annemarie Reinders, Husain Shabeeh and Andrew H. Shennan, 2002

Background

The market for devices for the selfmeasurement of blood pressure is growing, and as accuracy is of prime importance, there is increasing pressure for manufacturers to provide evidence of independent testing. Recent reviews have shown that only five automated upper arm devices for selfmeasurement of blood pressure have been recommended for use. We tested the Microlife BP 3BTO-A, a lightweight, upper arm, automated oscillometric device, according to a modified version of the British Hypertension Society protocol and also analysed the computer-generated oscillograms for possible causes of inaccuracy.

Methods

One hundred and twenty-six subjects were recruited from general medical and specialist clinics and from amongst the staff at Guy’s and St Thomas’ Hospital, London, UK. Only 85 of these were included in the final analysis. Nine sequential readings were taken by two trained observers alternating between the mercury sphygmomanometer and the device. The last
seven readings were analysed according to the British Hypertension Society protocol. Modifications to the protocol were: (1) the exclusion of patients whose blood pressure varied by more than 15mmHg between sequential observer readings and (2) limited testing in the low systolic pressure range.

Results

The Microlife achieved a grade A for both systolic and diastolic pressure according to the British Hypertension Society protocol. The mean differences (standard deviation) between the observers and the device were -1.6 (7.7) mmHg and -2.1 (6.3) mmHg for systolic and diastolic blood pressure, respectively, therefore also fulfilling the criteria set by the Association
for the Advancement of Medical Instrumentation. Subanalysis for different pressure ranges showed that the device was less accurate in the high-pressure range (4160/100 mmHg).

Conclusion

The Microlife can be recommended for clinical use in an adult population. 

Click here to download abstract as PDF